For example the national electric code requires no greater than 25 ohms of resistance in a ground system.

Ground rod resistance measurement.

The lower the number of ohms of resistance a grounding system has the better your protection is. Rloop 10 ω 0 17 ω 10 17 ω. That is why you have to fully familiarize yourself with your clamp on tester before you use it to measure resistances. In facilities with sensitive equipment it should be 5ohms or less.

If when taking further readings e you notice an increase of more than 20 from the safe reading of 25ohms or an increase of 20 from your last reading it is highly recommended you investigate the source of the problem. The ability to properly measure ground resistance is essential in preventing costly downtime due to service interruptions caused by poor grounds. Nearly all electricians and electrical inspectors are familiar with the national electrical code requirement in sec. If there were 60 similar ground electrodes with a resistance of 10 ω each the measurement of the total loop resistance would be.

An ideal ground rod resistance should be below 3 ohms. Resistance 2 rods 2 5 ohms 2 rods 1 16 1 45 ohms resistance 3 rods 2 5 ohms 3 rods 1 29 1 075 ohms resistance 4 rods 2 5 ohms 4 rods 1 36 0 85 ohms. Used for measuring resistance to earth of an installed grounding electrode. 250 54 which requires the resistance to ground of a single made electrode e g ground rod to be 25 ohms or less.

Video of the day volume 0. The nfpa and ieee recommend a ground resistance value of 5 ohms or less while the nec has stated to make sure that system impedance to ground is less than 5 ohms specified in nec 50 56. Method 1 using a clamp on ground meter. Thus if your first ground rod measures 2 5 ohms we would expect the resistance of multiple rods to be the following.

A current is applied across the outermost pair of stakes and the voltage drop across the inner pair is measured with a ground resistance meter. Make sure that your clamp on tester s jaws are fully closed as a semi opened clamp will significantly alter the measurement of the ground rod s resistance. Most of these agencies recommend a ground rod resistance reading or less than 5ohms when using a clamp on meter. Before measurements of ground resistance are conducted with a ground rod soil or ground resistivity testing is usually conducted with a series of four evenly spaced stakes.

Pin On Tools

Pin On Tools

Electrical Earthing Methods And Types Of Earthing Grounding Earthing Grounding Electricity Electrical Installation

Electrical Earthing Methods And Types Of Earthing Grounding Earthing Grounding Electricity Electrical Installation

Pin On Tools

Pin On Tools

Grounding Arrl The Doctor Will See You Now Podcast Ham Radio Antenna Ham Radio Radio Shop

Grounding Arrl The Doctor Will See You Now Podcast Ham Radio Antenna Ham Radio Radio Shop

Source : pinterest.com